J. George, D. A. Clymer, T.L. Turflinger, Larry W. Mason, Stephen E. Stone, R. Koga, Elizabeth Francis Beach, K. Huntington, Jean‐Marie Lauenstein, J.L. Titus,

IEEE Transactions on Nuclear Science · 2016 · 13 citations · 15 references

DOIFull text

Open access

Concepts

Abstract

Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text {V}_{\mathrm { {DS}}}$ </tex-math></inline-formula> ) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Burn-in is shown to be a critical factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.