2017 · 10 citations · 9 references
EngineeringElectrical EngineeringMaterials ScienceAcousticsMicroelectromechanical SystemsSensorsAcoustic SensorsMems DesignMems SensorsMicroelectromechanical SensorsPiezoelectric ActuatorsPiezoelectric MaterialsElectrode DesignMems MicrophonesMicroelectromechanical Systems MicrophonesMicrophone SensitivityMicrophonesPiezoelectric SensingProcess Variation EffectsStress Distribution
This study based on piezo-electric sensing principle to develop a high S/N ratio MEMS microphone. The patterned PZT and electrodes designed implemented above the clamped diaphragm to generate high stress concentration on PZT and Si bimorph diaphragm. The proposed central-circle electrode design can induce more charge than the edge-surrounded electrode design (served as the reference design). The proposed design also provides a smooth stress distribution across electrode to tolerate more process variation such as offset from double-side alignment and boundary change by DRIE undercut. The measured results demonstrate the S/N is about 64dB (reference design: 53dB) for the piezo-electric microphone.
9
Micromachined piezoelectric membrane acoustic device
Sang Choon Ko, Yong Chul Kim, Seung Seob Lee et al. · Sensors and Actuators A Physical · 2002 · 223 citations
Piezoelectric microphone with on-chip CMOS circuits
R.P. Ried, Eun Sok Kim, David M. Hong et al. · Journal of Microelectromechanical Systems · 1993 · 131 citations
Engineering, Physics, Acoustics +15
A MEMS Condenser Microphone for Consumer Applications
J.W. Weigold, Tim Brosnihan, Joe Bergeron et al. · 2006 · 128 citations
Engineering, Mechanical Engineering, Microelectromechanical Systems +16