Cross-Bridge Kelvin Resistor Structures for Reliable Measurement of Low Contact Resistances and Contact Interface Characterization

N. Stavitski, J.H. Klootwijk, H.W. van Zeijl, Alexey Y. Kovalgin, R.A.M. Wolters

IEEE Transactions on Semiconductor Manufacturing · 2009 · 51 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

The parasitic factors that strongly influence the measurement accuracy of Cross-Bridge Kelvin Resistor (CBKR) structures for low specific contact resistances (¿ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> ) have been extensively discussed during last few decades and the minimum of the ¿ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> value, which could be accurately extracted, was estimated. We fabricated a set of various metal-to-metal CBKR structures with different geometries, i.e., shapes and dimensions, to confirm this limit experimentally and to create a method for contact metal-to-metal interface characterization. As a result, a model was developed to account for the actual current flow and a method for reliable ¿ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> extraction was created. This method allowed to characterize metal-to-metal contact interface. It was found that in the case of ideal metal-to-metal contacts, the measured CBKR contact resistance was determined by the dimensions of the two-metal stack in the area of contact and sheet resistances of the metals used.

References

8