Analytical Methods · 2011 · 14 citations · 10 references
AgricultureFood ScienceChromatographic AnalysisFood AnalysisFood ChemistryAnalytical ChromatographyFruit Juice ExtractionFruit QualityPhenolic Compound AnalysisChromatographic Analysis Of PhenolicsFruit FlavonoidsFruit PhytochemicalsJuice Composition AnalysisPhenolic Content AnalysisPhenolic QuantificationPhytochemical Quality
A fast SPE-HPLC method is described for the analysis of flavonoids in apple juice. The mobile phase used was water-acetonitrile (60 : 40, v/v) at 0.80 mL min−1 flow rate with UV detection at 252 nm. The column used was new generation Halo C18 (100 × 46 mm; shell particles; 2.7 μm). The capacity factors were in the range of 0.67 to 20.56, respectively. The separation and resolution factors ranged from 1.18–2.21 and 1.00–10.00, respectively. The values for LOD and LOQ for flavonoids ranged from 0.40–5.5 ng and 2.25–26.0 ng, respectively. The linearity was observed in the concentration ranges of 0.01 to 0.10 mg mL−1 for all flavonoids. The concentrations of quercetin, apigenin, kaemferol and chrysin in apple juice were 4.00, 0.50, 0.40 and 0.25 mg kg−1, respectively. Therefore, the reported method can be used for the quality control of apple juice in food industries. Besides, this method can also be used for the analyses of flavonoids in other fruits and vegetables.
10
Quercetin: A Versatile Flavonoid
P Lakhanpal · Internet Journal of Medical Update - EJOURNAL · 2007 · 370 citations · Full text