IEEE Electron Device Letters · 1991 · 12 citations · 5 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsMetallurgySemiconductor DevicesCarrier TransportCurrent DistributionElectrical CharacterizationMetal MaterialsMetalsSemiconductor ReliabilityCurrent DensityCurrent Stress ReliabilityElectromigrationElectromigration AnalysisElectromigration ReliabilityLifetimesPolarity DependenceTungsten-based Materials
Using Kelvin test structures, electromigration performances of selective CVD tungsten filled vias under DC, pulsed DC, and AC current signals have been studied. The metallization consists of Al-Cu/TiW multilevel metals. The via electromigration lifetime exhibits a current polarity dependence. The via AC lifetimes are found to be much longer (more than 1000*) than DC lifetimes under the same peak stressing current density. The via lifetimes under pulsed DC stress of 50% duty factor are twice the DC lifetimes at low-frequency regions (<200 Hz) and 4-5 times the DC lifetimes at high-frequency regions (>10 kHz). The results are in agreement with the vacancy relation model.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
5