Safe operating area for 1200-V nonlatchup bipolar-mode MOSFET's

A. Nakagawa, Yoshio Yamaguchi, K. Watanabe, Hiromichi Ohashi

IEEE Transactions on Electron Devices · 1987 · 39 citations · 8 references

Concepts

Abstract

This paper reports the safe operating area (SOA) for 1200-V nonlatchup bipolar-mode MOSFET's. The measured SOA limit, in terms of current density and drain-voltage product, reached 2.5 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup> W/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> for 125°C-case temperature and 10-µs pulse operation conditions. It exceeded even the so-called "avalanche limit" for n-p-n bipolar transistors when the measurement was carried out under 25°C-case temperature conditions. These SOA's enable device protection from an abnormally large drain-current surge.

References

8