Japanese Journal of Applied Physics · 1996 · 14 citations · 19 references
Natural SciencesMaterials SciencePhysicsElectronic MaterialsPlasma PhysicsSpectroscopyHigh-temperature PlasmasMagnetized PlasmaPlasma DiagnosticsPlasma FundamentalsKinetic SpectroscopyMeasurement TechniquesOrganic Radical SpectroscopyPlasma ChemistryPlasma EtchingSelectivity
Diagnostics of fluorocarbon radicals and fluorine (F) atom species in a size-scaleable large-area permanent magnet electron cyclotron resonance (ECR) etching plasma employing CF 4 and C 4 F 8 gases are carried out. Non-intrusive infrared laser diode absorption spectroscopy and actinometric measurement techniques are used in evaluating the performance of the permanent magnet ECR plasma source and in studying the kinetic processes associated with etching plasma chemistry. Successful measurements of the absolute CF and CF 2 radical and F atom densities have been achieved. In particular for C 4 F 8 plasma, enhanced CF and CF 2 radical densities which afford higher selectivity in the etching of SiO 2 on Si are discussed. At a pressure of 0.4 Pa and an input microwave power of 900 W the CF and CF 2 radical and F atom densities in C 4 F 8 plasma were 1.7×10 13 cm -3 , 6.0×10 13 cm -3 and 1.5×10 13 cm -3 , respectively. These results are also discussed in comparison with results for a conventional electromagnet ECR plasma source.
19
Kôji Miyata, Masaru Hori, Toshio Goto · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · 1996 · 77 citations
Natural Sciences, Chemistry, Physics +14