Analysis of SOI CMOS Microprocessor's SEE Sensitivity: Correlation of the Results Obtained by Different Test Methods

Maxim S. Gorbunov, Boris V. Vasilegin, Andrey A. Antonov, Pavel N. Osipenko, Gennady I. Zebrev, Vasily S. Anashin, Vladimir V. Emeliyanov, Alexander I. Ozerov, Rustem G. Useinov, A. I. Chumakov,

IEEE Transactions on Nuclear Science · 2012 · 17 citations · 16 references

Concepts

Abstract

The results on SEE sensitivity of 0.5 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex Notation="TeX">$\mu$</tex></formula> m SOI CMOS microprocessor are presented and discussed. The comparative analysis of different test techniques (particle accelerator, pulsed laser technique and <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$^{252}$</tex></formula> Cf fission source) is provided for the cache. The possible sources of discrepancies between test results and the ways of data correction and methods of testing techniques' accuracy improvement are discussed.

References

16