Reliability Comparison of Aged SAC Fine-Pitch Ball Grid Array Packages Versus Surface Finishes

Zhou Hai, Jiawei Zhang, Chaobo Shen, John L. Evans, Michael J. Bozack, Munshi Basit, Jeffrey C. Suhling

IEEE Transactions on Components Packaging and Manufacturing Technology · 2015 · 52 citations · 12 references

Concepts

Abstract

Pb-free solder joints exposed to elevated isothermal temperatures for prolonged periods of time undergo microstructural and mechanical evolution, which degrades the joint electrical performance. We report the effect of isothermal aging on the reliability of Sn-Ag-Cu (SAC) assemblies on three different surface finishes [immersion Ag (ImAg), electroless Ni/immersion Au (ENIG), and electroless Ni/electroless Pd/immersion Au (ENEPIG)]. The characteristic life for SAC alloys in 10- and 15-mm ball grid array packages on ImAg degraded over 40% after an 85 °C/12 months aging and over 50% during a 125 °C/12 months aging. ENIG and ENEPIG outperformed ImAg for all aging treatments. For passive components (2512 resistors) on ImAg, the reliability performance degraded 16.7%/28.1% after a 1-year aging at 85 °C/125 °C. Failure analysis showed dramatic intermetallic binary Cu-Sn and ternary Ni-Cu-Sn film growth at the bottom of the solder joint interfaces for ImAg and ENIG/ENEPIG. For 125 °C-aged samples, the cracks appeared at the corners of both package and board sides of the solder ball and propagated along (near) the intermetallic compound location. For the case of aged fine-pitch packages, the failures tended to start at the component side solder ball corner and then propagate along an angled path downward into the bulk solder.

References

12