IEEE Transactions on Nanotechnology · 2024 · 10 citations · 45 references
EngineeringElectrical EngineeringMicroelectronicsSemiconductor DevicesSensorsDevice CharacterizationDevice ModelingDevice SimulationElectrochemical SensorsIon-selective ElectrodesPh AnalysisGallium Nitride (Gan) MaterialsPh MeasurementPh MonitoringPh SensingPh SensorsSensitivitySignal-to-noise RatioThreshold Voltage
This work proposed a recessed trench gate AlGaN/GaN HEMT for a potential of hydrogen ion (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\rm H^+$</tex-math></inline-formula>) sensing by eliminating the need for a reference electrode. The proposed device performance has been optimized by simulating the device with the help of the ATLAS device simulation tool, considering the pH model. The sensing surface has been functionalized with APTES to improve the sensor's performance to activate the binding sites. The impact of pH solution on the device characteristic alters the threshold voltage sensitivity, drain current sensitivity, and signal-to-noise ratio. The effect of gate voltage in terms of maximum <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\rm g_{m}$</tex-math></inline-formula> has also been optimized for the maximum sensitivity of the device to the pH solution. The device linearity has been utilized for <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\rm VIP_{3}$</tex-math></inline-formula>, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\rm IIP_{3}$</tex-math></inline-formula>, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\rm IMD_{4}$</tex-math></inline-formula>. The average threshold voltage sensitivity obtained is 160.56 mV/pH, higher than the Nernstian limit (59 mV/pH), and the current sensitivity obtained is 22.93 mA/mm.pH. The device's reliability has been optimized by addressing sensor output drift across various temperature and humidity conditions. These findings suggest that the proposed structure presents a promising alternative to current ion sensing techniques.
45
GaN-based heterostructures for sensor applications
M. Stutzmann, Gustav Steinhoff, Martin Eickhoff et al. · Diamond and Related Materials · 2002 · 166 citations