IEEE Transactions on Instrumentation and Measurement · 2003 · 91 citations · 9 references
EngineeringMechatronics EngineeringRobotics EngineeringAcousticsRoboticsUnderwater AcousticsAcoustic SensingAcoustic SensorsChaos TheorySonar SystemsTransducer TechnologyUltrasonicsContinuous FiringExteroceptive SensingPulse ModulationRobotic ApplicationsSonar SensorsUltrasonic SensingUltrasonic Sensors
Ultrasonic sensors are common in robotics for ranging, but concurrent operation of many sonars causes crosstalk. This study seeks to enhance ultrasonic sensor performance amid crosstalk and noise. The authors employ chaotic pulse position modulation to generate unique firing sequences, using a Polaroid 600 transducer driven by a continuous CPPM modulator and a detection filter to measure time of flight. Experimental results confirm the approach’s suitability.
Ultrasonic devices are widely used in robotics as exteroceptive sensors for ranging measurements. Robotic applications often involve a large number of sonars operating concurrently, giving rise to the phenomenon of crosstalk. In this work, the problem of improving performance of ultrasonic devices in the presence of crosstalk and noise is addressed. In order for each device to discriminate its own echo, chaos is exploited to create unique firing sequences. In particular, the firing scheme described in this work is inspired to a modulation scheme used in chaotic communications, called chaotic pulse position modulation (CPPM). The evaluation of the time of flight is performed by a detection filter. The experimental setup consists of a Polaroid 600 electrostatic transducer driven by a continuous CPPM modulator. Experimental results confirm the suitability of the approach.
9
Sinisa Pajevic · Journal of Statistical Physics · 1995 · 1.4K citations
G. Kolumbán, Michael Peter Kennedy, Leon O. Chua · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · 1997 · 347 citations · Full text