IEEE Transactions on Nuclear Science · 1990 · 18 citations · 21 references
EngineeringComputer EngineeringElectrical EngineeringMicroelectronicsRadiation SafetySemiconductor DevicesLow-dose Radiation EffectsRadiation HardeningAnnealingAnnealing EffectsAnnealing Time EffectsCmos ReliabilityComponent-level Radiation TestingRadiation-hardened Integrated CircuitsRadiation-hardening TechniquesTotal Dose
Low- and high-dose-rate testing results are compared for CMOS technologies. The long-term experiments extend over time periods of more than one year so that comparisons could be made over time frames more nearly like those in the space environment. High-temperature annealing is evaluated as a means of accelerating the annealing time and predicting low-dose-rate results. The data on hardened CMOS and CMOS/SOS devices show that for these particular processes, annealing at 100 degrees C did not accelerate trapped hole annealing. Differences between expected and actual results are identified, and recommendations are made for improving test procedures.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
21
Physical Mechanisms Contributing to Device "Rebound"
J.R. Schwank, P.S. Winokur, P. J. McWhorter et al. · IEEE Transactions on Nuclear Science · 1984 · 360 citations
The nature of the trapped hole annealing process
Aivars J. Lelis, Timothy R. Oldham, H. E. Boesch et al. · IEEE Transactions on Nuclear Science · 1989 · 310 citations