2002 · 27 citations · 8 references
MedicineRadiation OncologyDose-response ModelingRadiation DosimetryRadiation ProtectionAbsorbed DoseHigh-dose Radiation EffectsLow-dose Radiation EffectsRadiation SensitivityDose-rate EffectsDropout VoltageHardnessHardness TestingLow-dropout RegulatorsRate SensitivityTotal DoseTotal Ionizing Dose Effects
Total dose tests of six different low dropout voltage regulators show sensitivity to both dose rate and bias during exposure. All devices tested exhibited Enhanced Low Dose Rate Sensitivity (ELDRS) and performed worse for the unbiased irradiation condition. Behavior of critical parameters in different dose rate and bias conditions is compared and the impact on hardness assurance methodology is discussed.
8
Response of advanced bipolar processes to ionizing radiation
E.W. Enlow, R.L. Pease, W.E. Combs et al. · IEEE Transactions on Nuclear Science · 1991 · 322 citations