EngineeringIrradiation TestingRadiation ExposureRadiation ProtectionRadiation TestingAdvanced Bipolar ProcessesGain DegradationIon BeamIon EmissionElectrical EngineeringPhysicsRadiation-hard DesignBias Temperature InstabilityIonizing RadiationSingle Event EffectsRadiation TransportRadiation SafetyApplied PhysicsMedicineCrystalline Emitter Transistors
Ionizing radiation induced gain degradation in microcircuit bipolar polysilicon and crystalline emitter transistors is investigated. In this work, /sup 60/Co irradiation testing was performed on bipolar test structures. The effects of collector bias, dose rate, and anneal temperature are discussed. Major differences in the radiation response of polysilicon emitter transistors are demonstrated as a function of dose rate. The worst-case gain degradation occurs at the lowest dose rate complicating hardness assurance testing procedures. The dose rate and anneal data suggest that MIL-STD-883B Test Method 1019.4 is non-conservative for polysilicon emitter transistors, which show enhanced radiation hardness over the crystalline emitter transistors.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>