Improved Positioning Accuracy of the PA10-6CE Robot with Geometric and Flexibility Calibration

C. Lightcap, Sam Hamner, Tony L. Schmitz, Scott A. Banks

IEEE Transactions on Robotics · 2008 · 111 citations · 9 references

Concepts

Abstract

Accurate determination of robot geometric and flexibility parameters permits significant reduction of systematic errors and improved end-effector positioning accuracy. We apply a 30-parameter flexible geometric model to the Mitsubishi PA10-6CE robot and reduce mean/peak positional errors from 1.80/2.45 mm to 0.33/0.71 mm while loaded at 44 N.

References

9