Direct Determination of the Starch Content in Gravy by Near-Infrared Spectroscopy

Wei Zeng, Huizhen Zhang, Tung-Ching Lee

Journal of Agricultural and Food Chemistry · 1996 · 14 citations · 5 references

Concepts

Abstract

For the first time, a near-infrared transmission spectroscopic method has been developed to directly determine the starch content in a liquid gravy model system at low starch concentration (less than 5%). The best wavelengths for the model are 605, 623, 919, 1017, and 1031 nm. The regression equation is C = −3.62 − 10.47 a 1 − 14.39 a 2 − 29.24 a 3 + 25.26 a 4 + 50.15 a 5 . Using this method to directly determine starch content without any special treatment, we can easily and rapidly estimate the viscosity of liquid gravy and gravy-containing food products to carry out quality control. The time for analysis of one sample is less then 2 min. It is a rapid and nondestructive method and can be applied to on-line analysis at food-processing sites. Keywords: Starch; viscosity; gravy; near-infrared spectroscopy

References

5