Effect of passivation on the enhanced low dose rate sensitivity of National LM124 operational amplifiers

J.E. Seiler, D Platteter, G.W. Dunham, R.L. Pease, M.C. Maher, M.R. Shaneyfelt

2005 · 24 citations · 14 references

DOIFull text

Open access

Concepts

Abstract

This work presents high and low dose rate test results for LM124 operational amplifiers that were fabricated with six passivation layer types. Consistent with previous data, these results confirm that passivation layers play a significant role in determining ELDRS response. SIMS analysis suggests that an influential factor in determining the high and low dose rate response may be the location and concentration of hydrogen at the Si-SiO/sub 2/ interface and in the passivation layers.

References