Publication | Closed Access
Reliability study on cobalt and ruthenium as alternative metals for advanced interconnects
77
Citations
13
References
2017
Year
Unknown Venue
Reliability StudyEngineeringBeol InterconnectsRu Filled LinesInterconnect (Integrated Circuits)Bondpad DelaminationCorrosionElectronic PackagingMaterials ScienceElectrical EngineeringElectromigration TechniqueHardware ReliabilityMetallurgical InteractionAdvanced InterconnectsDevice ReliabilityElectrical PropertyAlternative MetalsMaterial AnalysisApplied PhysicsMaterial Performance
Cobalt and ruthenium are being proposed to replace copper in BEOL interconnects. Using intrinsic TDDB studies, we show that Co needs a barrier to prevent it from drifting into SiO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , where for Ru no drift into any of the three studied dielectrics is observed. Although our intrinsic EM studies on single damascene lines filled with Co suffered from bondpad delamination and a non-optimized CMP, we could still conclude that the EM-performance is better compared to Cu filled lines, where a much better performance of Ru filled lines is demonstrated (>25×). Via failures on Ru schemes show a > 5× higher lifetime compared to Cu schemes.