IEEE Sensors Journal · 2017 · 18 citations · 30 references
EngineeringElectrical EngineeringRobotics EngineeringHumanoid RoboticsRoboticsSensorsBiomedical SensorsCapacitive SensingRobot SensorsTactile SensingCapacitive Readout CircuitsCapacitive Tactile SensingCapacitive Tactile SensorsParasitic EffectsPower ConsumptionReadout ElectronicsTactile SensorsTactile Skin
This paper presents a robust, capacitive digital readout circuit (ROC) for sensitive skin applications in humanoid robots. The ROC can be calibrated to null the parasitic effects of transducer variation due to physical assembly. A prototype is fabricated in a 130 nm RFCMOS process, with an active area of 221 × 79 μm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and 1.84 μW power consumption at V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DD</sub> = 1.2V and 1ms read-out rate. The ROC output is robust to V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DD</sub> and temperature variations in a range |ΔV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DD</sub> | ≤ 20% and (25-53)°C. Furthermore, it can provide up to 200mV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</sub> power supply sine wave rejection in the range 50Hz-5MHz at V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DD</sub> = 1.1V, for an output standard deviation lower than one LSB. Owing to its features and its digital modularity, the ROC was co-designed with a scalable and modular Multi-Walled Carbon NanoTube (MW-CNT) Nano composite transducer, to achieve tunable output sensitivity by adjusting the sensor nominal capacitance and the reference capacitance. The maximum sensitivity of 5.23 fF per LSB was reached when both match. The ROC was then validated with the MW-CNT nanocomposite sensor which exhibits a piecewise behaviour. 5.3 and 7.1 ENOB were extrapolated in the low-load and medium-load regions, respectively. Besides the major advantage of tunable sensitivity, the presented ROC features the lowest acquisition time and one of the most compact sizes among the state-of-the-art ROCs. Moreover, process voltage and temperature (PVT) robust output and ultralow power consumption make this solution very attractive to replicate human physiology at robotic-level.
30
Tactile Sensing—From Humans to Humanoids
Ravinder Dahiya, Giorgio Metta, Maurizio Valle et al. · IEEE Transactions on Robotics · 2009 · 1.8K citations · Full text
Engineering, Mechanical Engineering, Robotics Engineering +17
Highly Sensitive Skin‐Mountable Strain Gauges Based Entirely on Elastomers
Nanshu Lu, Chi Lu, Shixuan Yang et al. · Advanced Functional Materials · 2012 · 821 citations