IEEE Transactions on Robotics and Automation · 1991 · 58 citations · 13 references
EngineeringComputer ScienceRobotics EngineeringMachine VisionRobot VisionRoboticsCalibrationCoordinate MeasurementPose EstimationRobot CalibrationRobotic VisionSensor CalibrationNonlinear RegressionNonlinear Regression ModelsParameter IdentificationPrecision MachiningResolution EnhancementResolution Enhancement TechniquesRobotic CalibrationSystem Calibration
An automatic partial-pose measurement system for robot calibration, called the vision-based automatic theodolite (VBAT), is described. It uses low-resolution rotation stages and resolution enhancement from a vision system to determine the line of sight to a spherical illuminated target. Automatic tracking, focusing, and centering provide the calibration system with speed, reliability, and repeatability. It is proposed that such a measurement prototype may be constructed without expensive precision machining, provided it is calibrated before use. Simulations demonstrate that such a system may be identified by precalibration of the vision parameters, followed by calibration of the rotation stage parameters. All parameters are determined from measurements using a coordinate measuring machine. The parameter identification is formulated as a nonlinear regression problem. Verification of the VBAT calibration experiment shows that the identified model can predict the target position to a root mean square miss-distance of 0.2 mm.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
13
Henry W. Stone, Arthur C. Sanderson, Charles P. Neuman · 1986 · 129 citations
Engineering, Mechanical Engineering, Robotics Engineering +17