Comparison of Visible and Near-Infrared Reflectance Spectroscopy to Authenticate Fresh and Frozen-Thawed Swordfish (<i>Xiphias gladius</i>L)

Luca Fasolato, Stefania Balzan, Roberto Riovanto, Paolo Berzaghi, Massimo Mirisola, Jacopo Carlo Ferlito, Lorenzo Serva, F. Benozzo, Roberto Passera, Valentina Tepedino,

Journal of Aquatic Food Product Technology · 2012 · 45 citations · 23 references

Concepts

Abstract

This study evaluated near-infrared (NIR) and visible-NIR (Vis-NIR) spectroscopy as a way to distinguish fresh (F) from frozen-thawed (T) swordfish cutlets (Xiphias gladius). A total of 90 F and 60 T samples were used. The T samples were stored at a high and low frozen temperature (HT: −10°C; LT: −18°C). Spectra were collected using a Vis-NIR portable spectrophotometer (380–1080 nm) and a NIR monochromator (1100–2500 nm). The percentage of correctly classified samples obtained with Vis-NIR spectroscopy was ≥ 96.7%, whereas that for NIR was ≥ 90.0%. The best classification was observed comparing F and HT samples using Vis-NIR (100 vs. 96.7%, respectively). The more descriptive principal component scores (PCS) of NIR and Vis-NIR were used with a multivariate binary logistic regression. The model with the PCS of the first two Vis-NIR principal components accounted for 81.1% of the classification. Vis-NIR could be a strategic tool to screen the cold treatment of swordfish.

References

23