A modified VERI‐FRY® quick test for measuring total polar compounds in deep‐frying oils

Xin‐Qing Xu

Journal of the American Oil Chemists Society · 1999 · 20 citations · 8 references

Concepts

Abstract

Abstract The AOCS official method for the determination of total polar compounds in deep‐frying oils is often used to estimate frying oil degradation. It can be accurate and reliable, but with sacrifices of time and expense. The TPM VERI‐FRY® PRO (Libra Technologies, Inc., Metuchen, NJ) quick test provides a quick and easy way to measure polar compounds in frying oils. The modified quick test measured at 490 nm has a good correlation with the AOCS official method ( r =0.975, P <0.001) and provides a good estimate of polar compound accumulation in oils over 80 h of deep‐frying. Using the quick test to measure polar compounds is fast, convenient, economical and reliable.

References

8