Journal of Mechanisms and Robotics · 2019 · 40 citations · 38 references
EngineeringRehabilitation MedicineRobotics EngineeringOrthoticsRehabilitation EngineeringRoboticsGait RehabilitationOrthotic DevicesRehabilitation BiomechanicsRehabilitation RoboticsRobotic ExoskeletonsRobotic RehabilitationExoskeleton BiomechanicsExoskeleton RehabilitationExoskeletonsGait AssistanceGait Assistance DevicesMedical ExoskeletonsOrthotic RobotsRobotic Orthoses
Abstract Walking rehabilitation using exoskeletons is of high importance to maximize independence and improve the general well-being of spinal cord injured subjects. We present the design and control of a lightweight and modular robotic exoskeleton to assist walking in spinal cord injured subjects who can control hip flexion, but lack control of knee and ankle muscles. The developed prototype consists of two robotic orthoses, which are powered by a motor-harmonic drive actuation system that controls knee flexion–extension. This actuation module is assembled on standard passive orthoses. Regarding the control, the stance-to-swing transition is detected using two inertial measurement units mounted on the tibial supports, and then the corresponding motor performs a predefined flexion–extension cycle that is personalized to the specific patient’s motor function. The system is portable by means of a backpack that contains an embedded computer board, the motor drivers, and the battery. A preliminary biomechanical evaluation of the gait-assistive device used by a female patient with incomplete spinal cord injury at T11 is presented. Results show an increase of gait speed (+24.11%), stride length (+7.41%), and cadence (+15.56%) when wearing the robotic orthoses compared with the case with passive orthoses. Conversely, a decrease of lateral displacement of the center of mass (−19.31%) and step width (−13.37% right step, −8.81% left step) are also observed, indicating gain of balance. The biomechanical assessment also reports an overall increase of gait symmetry when wearing the developed assistive device.
38
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Jan F. Veneman, R. Kruidhof, Edsko E.G. Hekman et al. · IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2007 · 1.3K citations · Full text
Engineering, Rehabilitation Medicine, Robotics Engineering +17
Alberto Esquenazi, Mukul Talaty, Andrew Packel et al. · American Journal of Physical Medicine & Rehabilitation · 2012 · 929 citations
Compliant actuation of rehabilitation robots
Heike Vallery, Jan F. Veneman, Edwin van Asseldonk et al. · IEEE Robotics & Automation Magazine · 2008 · 448 citations
Engineering, Biomedical Engineering, Robotics Engineering +17