Publication | Closed Access
Comparison of single-event transients induced in an operational amplifier (LM124) by pulsed laser light and a broad beam of heavy ions
55
Citations
6
References
2004
Year
EngineeringLaser-plasma InteractionHigh-power LasersIon BeamElectrical EngineeringPhysicsDifferent Voltage ConfigurationsRelativistic Laser-matter InteractionIndividual Transient ShapesAtomic PhysicsSingle Event EffectsNatural SciencesSpectroscopyLaser LightApplied PhysicsSingle-event TransientsLaser-induced BreakdownOperational AmplifierOptoelectronics
A comparison of single-event transients (SETs) from heavy-ion and pulsed-laser irradiation of the LM124 operational amplifier shows good agreement for different voltage configurations. The agreement is illustrated by comparing both individual transient shapes and plots of transient amplitude versus width.