IEEE Transactions on Microwave Theory and Techniques · 1996 · 66 citations · 17 references
EngineeringElectrical EngineeringElectronic MaterialsMicroelectronicsSemiconductor DevicesDevice CharacterizationDevice ModelingDevice ReliabilityHigh-frequency Semiconductor DevicesTemperature MeasurementThermal Properties Of SemiconductorsCharge TrappingCharge Trapping AnalysisCharge Trapping EffectsPulse CharacterizationPulsed Operation
A pulsed measurement system can provide more than just isothermal characteristic data. An off-the-shelf system can determine rapidly the timing necessary for both pulsed-I-V and pulsed-S-parameter measurements to be isothermal and isodynamic. Instantaneous channel temperature may be determined. Thermal and charge-trapping effects can be separated and time constants measured. Full gain-derivative surfaces can be obtained far more efficiently than by spectral sweep measurements. Characteristics and transient effects following excursions beyond the safe-operating-area and into breakdown may be observed nondestructively.
17
Characterization of GaAs devices by a versatile pulsed I-V measurement system
A. Platzker, A. Palevsky, Samuel Nash et al. · 2002 · 80 citations
Engineering, Electrical Engineering, Electronic Materials +16