Japanese Journal of Applied Physics · 2004 · 16 citations · 10 references
EngineeringElectrical EngineeringPhysicsInstrumentationMicroelectronicsPlasma PhysicsCurrent-voltage CharacteristicsDevice CharacterizationElectrical MeasurementImpedance Matching CircuitsPlasma DiagnosticsCurrent-voltage CharacterizationEquivalent Circuit AnalysisEquivalent Circuit ModelingGas Pressure EffectsOn-wafer Measurement TechniquesPlasma ProcessesVoltage MeasurementVoltage Measurement Circuits
A new probe method, which can measure wafer voltage directly from the wafer back-side without fluctuating the plasma, was developed. This method clarified the effect of the bias power, gas pressure and gas component on wafer V pp , V dc , and V dc / V pp . In addition, current, voltage, and phase shift were measured with an impedance monitor (IM) installed between the matching network and the bias electrode. Furthermore, wafer V pp was calculated from IM data according to a devised equivalent circuit model. It was found that calculated wafer V pp agrees with actual wafer V pp within 3.4% when bias power is ranged from 200 W to 500 W.
10
Jeffery W. Butterbaugh, L. D. Baston, Herbert H. Sawin · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · 1990 · 83 citations