Japanese Journal of Applied Physics · 1991 · 23 citations · 6 references
EngineeringElectrical EngineeringMicroelectronicsRadiation DetectionSemiconductor DevicesDevice ModelingDevice ReliabilityIon ImplantationRadiation Dose MeasurementCarrier LifetimeCarrier Lifetime MeasurementIon Implantation EffectsMinority Carrier Lifetime MeasurementNear-threshold VoltageRadiation Damage EffectsThreshold Voltage
Photo-acoustic displacement (PAD) generated with a modulated laser beam pumping is studied for As + or B + implanted Si. At doses above 1×10 13 ions/cm 2 , the PAD has a close relationship to damage density. An ion implantation dose down to 2×10 9 ions/cm 2 can be detected by the PAD measurement. Doses below 2×10 10 ions/cm 2 can be monitored by minority carrier lifetime measurement. A non-destructive high-sensitive dose monitor can be achieved by the PAD and minority carrier lifetime measurements. This monitoring leads to tight control of the threshold voltage of a MOS transistor.
6