Submicron thermocouple measurements of electron-beam resist heating

Dachen Chu, D. Taner Bilir, R. F. W. Pease, Kenneth E. Goodson

Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · 2002 · 38 citations · 6 references

Concepts

Abstract

Pattern distortion caused by resist heating is believed to contribute significantly to errors in feature size and pattern placement. A number of models have been proposed to predict the temperature rise of resist heating but experimental results are scarce. We fabricated and calibrated thin film gold/nickel thermocouples with (400 nm)2 junction size and used these to measure work-piece heating during electron-beam exposure. Irradiation by a 15 kV electron beam of 600 nA and 2 μm radius caused a temperature rise of 70 K, about 15% lower than the calculated result. The discrepancy may be due to the differences between the energy deposition profiles used in modeling and those prevailing in the experiments.

References

6