Journal of Micromechanics and Microengineering · 2011 · 39 citations · 15 references
EngineeringElectrical EngineeringMicroelectromechanical SystemsOpticsSensorsIntegrated OpticsInterferometryMems FabricationMems SensorsMicromachiningOptical MemsDiffraction GratingsFabricationFabrication ProcessesLow-coherence InterferometryMicromachining Of Silicon WafersOptical InterferometersSilicon MicromachiningSilicon Wafers
We present the development of an array type of micromachined Mirau interferometers, operating in the regime of low coherence interferometry (LCI) and adapted for massively parallel inspection of MEMS. The system is a combination of free-space micro-optical technologies and silicon micromachining, based on the vertical assembly of two glass wafers. The probing wafer carries an array of refractive microlenses, diffractive gratings to correct chromatic and spherical aberrations and reference micro-mirrors. The semitransparent beam splitter plate is based on the deposition of a dielectric multilayer, sandwiched between two glass wafers. The interferometer matrix is the key element of a novel inspection system aimed to perform parallel inspection of MEMS. The fabricated demonstrator, including 5 x 5 channels, allows consequently decreasing the measurement time by a factor of 25. In the following, the details of fabrication processes of the micro-optical components and their assembly are described. The feasibility of the LCI is demonstrated for the measurement of a wafer of MEMS sensors.
15
Improved vertical-scanning interferometry
Akiko Harasaki, Joanna Schmit, James C. Wyant · Applied Optics · 2000 · 275 citations · Full text
Engineering, Manufacturing Engineering, Biomedical Optics +14