physica status solidi (a) · 1979 · 19 citations · 16 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsSemiconductor DevicesSemiconductor MaterialsDevice CharacterizationDevice ReliabilityIon ImplantationSemiconductor DefectsSemiconductor Device MaterialsSemiconductor ReliabilityAmorphizationCarrier LifetimeCarrier Lifetime MeasurementDislocation LoopsIon Implantation EffectsMicroscopyRadiation Damage EffectsRadiation Effects On Reliability
Minority carrier lifetime changes in MOS diodes implanted with 200 keV Ar+ or 80 keV Si+ in the dose range 1011 to 1016 ions/cm2 are investigated and related to the implanted ions and the damage in the substrate. Lifetime degradation observed after Ar+ implantation varies with the dose. A factor of 105 is achieved by implanting a dose of 1015 Ar+/cm−2. Contrarily Si+ implantation does not affect the lifetime up to 1014 Si+/cm2. For a higher Si+ dose the lifetime is reduced by four orders of magnitude. Transmission electron microscopy studies reveal no defects for implants up to 1012 Ar+/cm2 and 1014 Si+/cm2. At higher argon dose bubble like defects are identified. For Ar+ and Si+ ion doses close to the amorphization dose stacking faults and dislocation loops are observed additionally.
16
Surface Energy of Germanium and Silicon
R. J. Jaccodine · Journal of The Electrochemical Society · 1963 · 542 citations
Electrical Properties of Dislocations in Ge and Si
W. Schröter, R. Labusch · physica status solidi (b) · 1969 · 129 citations