IEEE Transactions on Power Electronics · 2022 · 44 citations · 21 references
EngineeringElectrical EngineeringMicroelectronicsPower ElectronicsSemiconductor DevicesDevice CharacterizationDevice ModelingIntegrated Circuit DesignSemiconductor Device MaterialsTiming AnalysisDynamic CharacterizationSemiconductor CharacterizationSemiconductor Device CharacterizationSilicon CarbideSilicon Carbide (Sic) MaterialsSilicon Carbide Power DevicesTiming AlignmentVoltage
This article presents an improved double pulse test (DPT) for accurate dynamic characterization of the medium voltage (MV) silicon carbide device. The difference between low voltage (LV) and MV DPT setup grounding is first introduced, which results in different measurement considerations. Then, parasitic capacitances in the DPT and their impact on the DPT are discussed considering different grounding points and device connections. Approaches are proposed to minimize the impact of parasitic capacitances on DPT results. In addition, the impact of switching V-I timing alignment on the testing results is discussed, compared to that in the LV DPT; a V-I alignment approach is introduced for the MV DPT. A 10 kV/20 A SiC <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">mosfet</small> -based DPT is taken as an example of the improved DPT, and test results show that it can minimize the impact from parasitic and improve the accuracy of the device switching loss estimation.
21
Silicon carbide power MOSFETs: Breakthrough performance from 900 V up to 15 kV
John W. Palmour, Lin Cheng, Vipindas Pala et al. · 2014 · 293 citations
Methodology for Wide Band-Gap Device Dynamic Characterization
Zheyu Zhang, Ben Guo, Fred Wang et al. · IEEE Transactions on Power Electronics · 2017 · 273 citations · Full text