Journal of Food Science · 2021 · 28 citations · 24 references
EngineeringFood ScienceMicrobiologyBiosensorsFood MicrobiologySensorsBiological SensorsElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsMicrobial BiosensorsNanomaterial-based BiosensorsCarbon Nanotube BiosensorsCarbon Nanotube SensorsElectrochemical BiosensingElectrochemical ImmunosensorsListeria DetectionNanobiosensorsNanomaterial-based ImmunosensorsSingle-walled Carbon Nanotubes
Abstract Real‐time and sensitive detection of pathogenic bacteria in food is in high demand to ensure food safety. In this study, a single‐walled carbon nanotubes (SWCNTs)‐based electrochemical impedance immunosensor for on‐site detection of Listeria monocytogenes ( L. monocytogenes ) was developed. A gold‐plated wire was functionalized using polyethylenimine (PEI), SWCNTs, streptavidin, biotinylated L. monocytogenes antibodies, and bovine serum albumin (BSA). A linear relationship ( R 2 = 0.982) between the electron transfer resistance measurements and concentrations of L. monocytogenes within the range of 10 3 –10 8 CFU/ml was observed. In addition, the sensor demonstrated high selectivity towards the target in the presence of other bacterial cells such as Salmonella Typhimurium and Escherichia coli O157:H7. To facilitate the demand for on‐site detection, the sensor was integrated into a smartphone‐controlled biosensor platform, consisting of a compact potentiostat device and a smartphone. The signals from the proposed platform were compared with a conventional potentiostat using the immunosensor interacted with L. monocytogenes (10 3 –10 5 CFU/ml). The signals obtained with both instruments showed high consistency. Recovery percentages of lettuce homogenate spiked with 10 3 , 10 4 , and 10 5 CFU/ml of L. monocytogenes obtained with the portable platform were 90.21, 90.44, and 93.69, respectively. The presented on‐site applicable SWCNT‐based immunosensor platform was shown to have a high potential to be used in field settings for food and agricultural applications. Practical Application The developed immunosensor was developed for on‐site detection of L. monocytogenes . The limit of detection of the sensor was 10 3 CFU/ml with a detection time of 10 min. In order to facilitate the requirements for effective on‐site screening for food safety, the sensor was integrated into a smartphone‐controlled platform, so that the bio‐molecular interactions were converted into impedance signals and transmitted wirelessly to a smartphone by a hand‐held EIS transducer.
24
Identifying the Mechanism of Biosensing with Carbon Nanotube Transistors
Iddo Heller, Anne M. Janssens, Jaan Männik et al. · Nano Letters · 2007 · 485 citations
Impedimetric immunosensors—A review
Mamas I. Prodromidis · Electrochimica Acta · 2009 · 343 citations