Acta Scientiarum. Technology/Acta scientiarum. Technology · 2019 · 17 citations · 14 references
EngineeringAgricultural EngineeringFood ScienceComputational Fluid DynamicsFood EngineeringHeat TransferEquipment DesignFood DryingGrain ProcessingSeed DryingCereal Grain DryingDryingEnergy ConsumptionGrain DryingHeat Transfer In DryingMathematical Modeling Of DryingPrototype EvaluationSpecific Energy Consumption
The aim of this study was to size up and evaluate a fixed bed experimental silo-dryer-aerator with four static grain drying cells for segregation lots, through simulations with mathematical equations and a computational fluid dynamics (CFD) system. The average specific energy consumption of the dryer was 2,998.56 kJ kg-1 of evaporated water. At the global scale, the amount of heat needed to complete a grain drying was 22,283.84 kcal (5,325.96 kJ kg-1) and the amount of heat required to complete the cooling of a stored grain mass was 3,525 kcal (842.49 kJ kg-1). The drying equipment responded positively to the dynamic aspects of air, distribution, flow, pressure, speed and heating. The results obtained allow us to conclude that the silo-dryer-aerator prototype was characterized as a viable and sustainable tool, making it possible to perform the drying and storage of grains in standardized and segregated lots, according to genetic characterization, minimizing quantitative and qualitative losses.