Journal of the Ceramic Society of Japan · 1989 · 13 citations · 0 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsSemiconductor DevicesSemiconductor MaterialsCurrent-voltage CharacteristicsDevice CharacterizationDevice ModelingOxide SemiconductorsSemiconductor Device MaterialsSemiconductor InterfacesCharge TrapsConduction BandInterface Trap StatesOxide Defect StatesTrap CharacterizationTrap LevelsTrap State AnalysisTraps
The isothermal capacitance transient spectroscopy (ICTS) was applied to ZnO-Bi2O3-MnO2 ternary varistor system. The ICTS signals caused by three trap levels were detected in three temperature ranges. The detected traps, which were calculated from the slope of Arrhenius plots of ln (τ·T2) vs 1000/T, located at 0.19, 0.29, and 0.60eV below the conduction band edge. The ICTS signals caused by the traps of 0.19 and 0.29eV had no dependence on the bias voltage, so that the detected levels were referred to the bulk traps. On the other hand, the signal caused by the trap of 0.60eV was referred to the interface state because the signal had the dependence on the bias voltage.