2003 · 39 citations · 3 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsMetallic MaterialsSemiconductor DevicesDevice ReliabilityDielectricsInterconnect TechnologyMaterial DeteriorationMetal MaterialsSemiconductor ReliabilityBreakdown VoltageCopper InterconnectsCopper MetallizationElectrical BreakdownIon MigrationLow-k DielectricsReliability Degradation MechanismsTime-dependent Dielectric Breakdown
Time-dependent dielectric breakdown (TDDB) of sub-half-micron Cu interconnects was investigated with regard to the waiting time between Cu-CMP and barrier dielectric deposition. Breakdown voltage and TDDB lifetime between adjacent Cu wires deteriorated abruptly as the waiting time in air passed 4 days. This is due to Cu-ion migration phenomena on the CMP-surface. The degradation can be improved by keeping the samples in a N/sub 2/-box or adopting post-cleaning. This TDDB degradation was observed on any Cu barrier dielectrics in this experiment. In addition, another phenomenon related to Cu TDDB lifetime was discovered, namely a 'fine line effect'. As Cu wire width becomes finer, the TDDB lifetime also decreases further because of the interaction of the electric field at the CMP-surface. It was predicted that the TDDB lifetime for next-generation technology was possibly insufficient for 10-year reliability by testing several low-k dielectrics and Cu barrier dielectrics.
3
TDDB improvement in Cu metallization under bias stress
J. Noguchi, N. Ohashi, J. Yasuda et al. · 2002 · 23 citations
Natural Sciences, Electrical Engineering, Materials Science +17