Transient Response of Semiconductor Electronics to Ionizing Radiation. Recent Developments in Charge-Collection Measurement
26
Citations
16
References
2007
Year
EngineeringCharge-collection MeasurementsCharge TransportGaas HfetsSemiconductor ElectronicsSemiconductor DeviceRf SemiconductorNanoelectronicsElectronic EngineeringRecent MeasurementsInstrumentationDevice ModelingElectrical EngineeringRadiation DetectionPhysicsIonizing RadiationMicroelectronicsTransient ElectronicsApplied PhysicsTransient ResponseElectronic InstrumentationOptoelectronics
Recent measurements of heavy-ion-induced charge- collection transients are presented. These measurements are possible for the first time because of recent developments in high- bandwidth, single-shot measurement technology, and exhibit several significant advantages over conventional (charge-sensitive preamplifier) charge-collection measurements. Heavy-ion induced transient measurements are presented for InGaAs/InAlAs HEMTs, AlSb/InAs HEMTs, GaAs HFETs and for SOI NMOS devices, and the significant advantages of this approach are described.