Time-Resolved Evaporation Rate of Attoliter Glycerine Drops Using On-Chip CMOS Mass Sensors Based on Resonant Silicon Micro Cantilevers

María Villarroya Gaudó, G. Abadal, J. Verd, J. Teva, Francesc Pérez‐Murano, Eduardo Figueras Costa, J. Montserrat, A. Uranga, J. Estéve, N. Barniol

IEEE Transactions on Nanotechnology · 2007 · 10 citations · 12 references

Concepts

Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> The time-resolved evaporation rate of small glycerine drops (in the attoliter range) is determined by means of a mass sensor based on a resonant cantilever integrated in a CMOS chip. The cantilever is fabricated on crystalline silicon, using silicon-on-insulator (SOI) substrates for the integration of the CMOS-MEMS. Glycerine drops are deposited at the free end of the cantilever. The high mass sensitivity of the sensor (8 ag/Hz) allows to determine the evaporation rate for glycerine drops smaller than 500 aL, which are found to be below 3.2 aL/s in volume or 4 fg/s in mass. </para>