Vacuum packaging technology using localized aluminum/silicon-to-glass bonding

Yu Cheng, Wan-Tai Hsu, K. Najafi, Clark T.‐C. Nguyen, Liwei Lin

Journal of Microelectromechanical Systems · 2002 · 156 citations · 27 references

Concepts

Abstract

A glass vacuum package based on localized aluminum/silicon-to-glass bonding has been successfully demonstrated. A constant heat flux model shows that heating can be confined locally in the dielectric layer underneath a microheater as long as the width of the microheater and the thickness of silicon substrate are much smaller than the die size and a good heat sink is placed underneath the silicon substrate. With 3.4 W heating power, /spl sim/0.2 MPa applied contact pressure and 90 min wait time before bonding, vacuum encapsulation at 25 mtorr (/spl sim/3.33 Pa) can be achieved. Folded-beam comb drive /spl mu/-resonators are encapsulated and used as pressure monitors. Long-term testing of vacuum-packaged p-resonators with a Quality Factor (Q) of 2500 has demonstrated stable operation after 69 weeks. A /spl mu/-resonator with a Q factor of /spl sim/9600 has been vacuum encapsulated and shown to be stable after 56 weeks.

References

27