Journal of Micromechanics and Microengineering · 2011 · 95 citations · 13 references
EngineeringMechanical EngineeringMechanical Behavior Of MaterialsMicroelectromechanical SystemsMicrofabricationMems CharacterizationMems DesignMems FabricationMems ModelingMems ResonatorsMems SimulationAnchor LossAnchoringQuality FactorsResonant MemsResonator DesignResonator ModelingResonator Quality FactorStrain Energy
MEMS resonators fabricated in silicon-on-insulator (SOI) technology must be clamped to the substrate via anchoring stems connected either from within the resonator or through the sides, with the side-clamped solution often employed due to manufacturing constraints. This paper examines the effect of two types of commonly used side-clamped, anchoring-stem geometries on the quality factor of three different laterally-driven resonator topologies. This study employs an analytical framework which considers the relative distribution of strain energies between the resonating body and clamping stems. The ratios of the strain energies are computed using ANSYS FEA and used to provide an indicator of the expected anchor-limited quality factors. Three MEMS resonator topologies have been fabricated and characterized in moderate vacuum. The associated measured quality factors are compared against the computed strain energy ratios, and the trends are shown to agree well with the experimental data. © 2011 IOP Publishing Ltd.
13
H.C. Nathanson, W.E. Newell, R.A. Wickstrom et al. · IEEE Transactions on Electron Devices · 1967 · 1.1K citations
Materials issues in microelectromechanical systems (MEMS)
S.M. Spearing · Acta Materialia · 2000 · 652 citations
Göran Stemme · Journal of Micromechanics and Microengineering · 1991 · 289 citations