Journal of Food Process Engineering · 1998 · 14 citations · 10 references
AgricultureFood ScienceMicrobiologyBacteriologyFood EngineeringFood MicrobiologyBakery MicrobiologyFood BacteriologyMicrobial QualityAerobic Plate CountBacterial ReductionBactericidal AgentsFlour MicrobiologyPulsed Electric Field Treatment
ABSTRACT Pulsed electric fields (PEF) were tested for efficacy in bacterial reduction in dark rye flour. Field strengths greater than 20kV/cm resulted in approximately 0.6‐log reduction of aerobic plate counts. Bactericidal effect was related to field strength, pulse polarity, pulse width, and pulse number. Changing pulse period and altering gas atmosphere did not improve bactericidal effect. Reversing polarity pulses were more effective than synchronized bipolar pulses.
10
Food application of high electric field pulses
Dietrich Knorr, Manuela Geulen, Thomas Grahl et al. · Trends in Food Science & Technology · 1994 · 280 citations
Food pasteurization using high-intensity pulsed electric fields
Bingbin Qin, Usha R. Pothakamury, Olga Martín‐Belloso et al. · Food technology · 1995 · 228 citations