Journal of Micromechanics and Microengineering · 2007 · 75 citations · 14 references
EngineeringMechanical EngineeringMicroelectromechanical SystemsMicrofabricationSensorsMass MeasurementMechanical SensorsMems ResonatorsMems SensorsMicroelectromechanical SensorsVibration MeasurementAtmospheric PressureMass SensingMass SensorsQuality FactorsResonator Quality FactorVibration Mode AnalysisVibration Mode ShapesVibration Modes
The detection limit of a resonant cantilever mass sensor depends on its quality factor. The size and mode dependences of quality factors in silicon micro-cantilevers at atmospheric pressure are extensively investigated. Silicon micro-cantilevers of various lengths and widths are fabricated and their quality factors of flexural vibration modes are measured in air. The quality factor is found to vary largely depending on the cantilever length, width and vibration mode. The maximum quality factor obtained is 1550. These findings correlate well with a vibrating sphere model with an equivalent cross-section approximation.
14
Dependence of the quality factor of micromachined silicon beam resonators on pressure and geometry
F.R. Blom, S. Bouwstra, Michael Curt Elwenspoek et al. · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · 1992 · 445 citations · Full text
Engineering, Mechanical Engineering, Microelectromechanical Systems +16
Virus detection using nanoelectromechanical devices
B. Ilic, Yi Yang, H. G. Craighead · Applied Physics Letters · 2004 · 363 citations