Journal of the American Oil Chemists Society · 1943 · 59 citations · 2 references
AgricultureFood ScienceFood AnalysisFood EngineeringGood Laboratory PracticeOxidation AnalysisOxidative StabilityOxidative Stability AssessmentOxidative Stability TestingStability Test Procedure
The study introduces an all‑glass aeration tube and enhanced air‑distributing apparatus for the Swift stability test of fats. The authors describe a single‑tube procedure that employs the new apparatus, examining the effects of air, reaction time, sample size, and reagent amounts. Using this method, the same number of stability tests can be performed on one standard apparatus as with three units, and the authors report observations on Wheeler‑style peroxide determinations.
An all-glass aeration tube and improved air-distributing apparatus are described for use in the Swift stability test or similar accelerated method of determining stability of fats. A procedure is described in which only one tube is required for each test sample. By this procedure, it is possible to carry out as many stability tests simultaneously on one standard apparatus as on three such units by the usual three-tube method. Observations on the use of adaptations of Wheeler's method of determining peroxide values are reported. The effects of air, time of reaction, size of sample, and quantities of reagents were investigated.
2