EngineeringElectrical EngineeringMaterials ScienceSemiconductor DevicesSemiconductor MaterialsThin FilmsDetector TechnologyDevice CharacterizationPhotodetectorsSemiconductor DetectorsSemiconductor Thin FilmsThin Film Electrical PropertiesAmorphous SiliconDetector Spatial ResolutionHydrogenated Amorphous SiliconPosition-sensitive DetectionSilicon DetectorsSilicon Semiconductor DetectorsSpatial Resolution MeasurementThin-film Detectors
The aim of this work is to present an analytical model able to interpret the role of the thin collecting resistive layer on the static performances exhibited by 1D amorphous silicon hydrogenated p-i-n thin film position sensitive detectors. The data obtained show that the devices present a linearity and a spatial resolution, of respectively, better than 99% and 20 μm for a spatial detection limit of about 80 mm, highly dependent on the characteristics exhibited by the collecting resistive layer that should have sheet resistivities in the range of 10 to 103 Ω/sq, as predicted by the model proposed.