Establishing Thermal Processes for Heterogeneous Foods to be Processed Aseptically: A Theoretical Comparison of Process Development Methods

Dilip I. Chandarana, A. Gavin

Journal of Food Science · 1989 · 52 citations · 13 references

Concepts

TL;DR

The study develops a mathematical model to predict heat transfer into particulate foods in a continuous aseptic system and uses it to design thermal processes for a commercial sterile product. The authors theoretically design thermal processes, evaluating heat transfer, nutrient retention, and microbial inactivation across particle sizes. Neglecting the heat exchanger’s contribution can inflate the effective F₀ to 78 min and increase nutrient loss to 13.6–18.6 % versus 6–17 % with proper modeling.

Abstract

ABSTRACT A mathematical model for predicting heat transfer into particulate foods processed in a continuous aseptic system was developed. Various approaches were taken to theoretically design thermal processes for a commercially sterile model product. The impact of the thermal treatment on possible nutrient retention and on accumulated microbial effectiveness was assessed. Comparison of the approaches presented indicated that neglecting the thermal contribution of a heat exchanger while scheduling the thermal process for a particle center F o of 6.0 min could result in an effective F o of as high as 78 min. In addition, such a conservative approach can result in higher nutrient destruction, 13.6% to 18.6%, instead of 6% to 17% depending on particle size.

References

13