EngineeringBioengineeringFood ScienceBiosensorsFish BiologySensorsAquaculture InstrumentationAquaculture MonitoringOptical BiosensingOptical BiosensorsOptical SensorsPh AnalysisBiosensor CharacterizationDetector Response StabilityFish Freshness AssessmentLinearityPh MonitoringPh SensingPh SensorsSensor Response Time
In a simple and instant procedure for detecting fish freshness, a hydrogel and hydrophilic pectin matrix membrane was used successfully as an optical pH sensor by immobilizing the chromoionophore ETH 5294 (CI), which is very selective and sensitive for the membrane. The Pe/CI optical pH sensor exhibited excellent linearity between pH 5 and pH 9, with a sensor response time of 5 min and reproducibility of 1.49% relative standard deviation (RSD). The sensor showed response stability for 15 days and a response reduction of 8.6%. The sensor's capability was demonstrated by the detection of fish freshness for 17 days at 4 °C.
20
A novel colorimetric food package label for fish spoilage based on polyaniline film
Bambang Kuswandi, Jay Jayus, Anggi Restyana et al. · Food Control · 2011 · 343 citations
Development of a volatile amine sensor for the monitoring of fish spoilage
A. Pacquit, Kim Lau, Henry McLaughlin et al. · Talanta · 2005 · 300 citations
Agriculture, Fisheries, Food Science +12
Multisensor for fish quality determination
G. Ólafsdóttir, P. Nesvadba, Mercedes Careche et al. · Trends in Food Science & Technology · 2003 · 278 citations
Selectivity of ion-sensitive bulk optodes
Eric Bakker, W. Simon · Analytical Chemistry · 1992 · 233 citations