Molecules and Cells · 2016 · 34 citations · 25 references
EngineeringBiotechnologyMicrobiologyBiosensorsDiagnostic MicrobiologyMolecular BiotechnologyAptamer-based BiosensorsBiosensor DesignCell-based BiosensorsNucleic Acid BiosensorsOptical BiosensingPathogen DetectionAptamer BiosensorsAptamer-based BiosensingCell-selexEscherichia ColiIndicator Organisms MonitoringReal-time Detection AssaysRna Aptamer BindingSelex
Escherichia coli are important indicator organisms, used routinely for the monitoring of water and food safety. For quick, sensitive and real-time detection of E. coli we developed a 2F modified RNA aptamer Ec3, by Cell-SELEX. The 31 nucleotide truncated Ec3 demonstrated improved binding and low nano-molar affinity to E. coli. The aptamer developed by us out-performs the commercial antibody and aptamer used for E. coli detection. Ec3(31) aptamer based E. coli detection was done using three different detection formats and the assay sensitivities were determined. Conventional Ec3( Although, optical analytic technique, biolayer interferometry, did not improve the sensitivity of detection for whole cells, a very significant improvement in the detection was seen with the E. coli cell lysate (5 10 4 CFU/ml). Finally we developed Electrochemical Impedance Spectroscopy (EIS) gap capacitance biosensor that has detection limits of 2 10 4 CFU/mL of E. coli cells, without any labeling and signal amplification techniques. We believe that our developed method can step towards more complex and real sample application.
25
Multiple sequence alignment with hierarchical clustering
F. Corpet · Nucleic Acids Research · 1988 · 5.4K citations · Full text