EngineeringElectrical EngineeringInstrumentationMicroelectronicsMicrowave EngineeringDevice CharacterizationElectrical MeasurementMicrowave Integrated CircuitsMicrowave MeasurementsMicrowave Passive ComponentsMicrowave Semiconductor DevicesElectro-optic SamplingMicrowave Component CharacterizationOn-wafer MeasurementOn-wafer Measurement TechniquesS-parameter CharacterizationS-parameter MeasurementS-parameter ModelingSensitivity
An S-parameter measurement system based on electro-optic sampling for the on-wafer testing of microwave integrated circuits is presented. Conventional network-analyser measurements on passive circuits up to 20 GHz are used to establish a calibration and measurement procedure to allow S21 measurement on further circuits with 0.5 dB uncertainty. Extension of these rules to the noninvasive testing of active microwave circuits, coupling waveguides and digital circuits is demonstrated with a spatial resolution of 8 µm and submillivolt sensitivity.