Thermomagnetic residual offset in integrated hall plates

Patrick Ruther, Ulf Schiller, Ralf Janke, Oliver Paul

IEEE Sensors Journal · 2003 · 28 citations · 6 references

Concepts

Abstract

Integrated Hall plates show self-induced offset due to the current flow in their current leads. The magnetic field surrounding these current leads generates a magnetic offset signal, while their resistive heating causes thermoelectric offset voltages. This paper reports experimental results on these two effects. They are obtained using a novel test structure enabling to separate the two contributions. In addition, the experimental results concerning the thermal behavior of the test structure are compared with finite element (FE) simulations.

References

6