2002 · 29 citations · 2 references
EngineeringComputer EngineeringElectrical EngineeringMechatronicsMicroelectromechanical SystemsSensorsAngle MeasurementAngular MeasurementDevice CharacterizationMagnetic SensorsAccuracyAngle Error AnalysisAngle Measurement Error SourcesAngle SensingAngular AccuracyHall EffectMagnetic Field DistributionTolerances
A novel method for contactless angle detection is presented. It is based on four Hall devices on a single industrial CMOS chip in combination with a permanent magnet. The system setup and the Hall devices implemented are described. Measurements show an angular accuracy of /spl plusmn/0.3/spl deg/ over the range of 360/spl deg/. We also measured the magnetic field distribution in the chip plane. Based on this, the robustness of the angular accuracy against mechanical tolerances is investigated. Lateral misalignment below 100 /spl mu/m of the chip or the magnet to the axis of rotation causes an angle error below /spl plusmn/1/spl deg/. A tilt of 1.5/spl deg/ between magnet and chip results in /spl plusmn/0.5/spl deg/. A worst case combination of the three effects still results in an accuracy better than /spl plusmn/3.6.
2
Offset reduction in Hall devices by continuous spinning current method
Reto Steiner, A. Hàberli, Franz-Peter Steiner et al. · 2002 · 14 citations