CoRoT Satellite: Analysis of the In-Orbit CCD Dark Current Degradation

O. Gilard, Cesar Boatella-Polo, J.C. Dolado-Perez, M. Auvergne, Gianandrea Quadri, Mathieu Boutillier

IEEE Transactions on Nuclear Science · 2010 · 20 citations · 13 references

Concepts

Abstract

This paper presents the analysis of the CoRoT CCDs dark current degradation measured during more than 2.5 years in orbit. Starting from on-ground irradiation results obtained during the space qualification of the detectors, a model is proposed to calculate the in-orbit pixel dark current distribution (including the hot pixels one). The modeling results are found to be in good agreement with the in-flight data. We therefore use this model to extrapolate the evolution of the dark signal distribution beyond 2.5 years. This is of primary interest in the context of a mission duration extension to 6 years proposed for the CoRoT mission.

References

13